高志宇,黄有骏,罗庭芳,孙琦,龚涛波.反应堆中子倍增特性分析及标定技术研究[J].南华大学学报(自然科学版),2023,(5):52~55, 74.[GAO Zhiyu,HUANG Youjun,LUO Tingfang,SUN Qi,GONG Taobo.Analysis of Neutron Multiplication Characteristics of Reactors and Study on Calibration Technique[J].Journal of University of South China(Science and Technology),2023,(5):52~55, 74.]
反应堆中子倍增特性分析及标定技术研究
Analysis of Neutron Multiplication Characteristics of Reactors and Study on Calibration Technique
投稿时间:2023-03-20  
DOI:10.19431/j.cnki. 1673-0062.2023.05.008
中文关键词:  反应堆周期  信号发生  标定技术
英文关键词:reactor period  signal generation  calibration technology
基金项目:
作者单位E-mail
高志宇 中国核动力研究设计院 核反应堆系统设计技术重点实验室,四川 成都 610041 gzy85930@sina.com 
黄有骏 中国核动力研究设计院 核反应堆系统设计技术重点实验室,四川 成都 610041  
罗庭芳 中国核动力研究设计院 核反应堆系统设计技术重点实验室,四川 成都 610041  
孙琦 中国核动力研究设计院 核反应堆系统设计技术重点实验室,四川 成都 610041  
龚涛波 中国核动力研究设计院 核反应堆系统设计技术重点实验室,四川 成都 610041  
摘要点击次数: 84
全文下载次数: 72
中文摘要:
      针对反应堆用核测量仪表的反应堆周期测量标定问题,从理论推导和实堆数据验证两方面研究了反应堆中子倍增特性,并确定了使用指数变化规律的信号可以表征反应堆中子注量率随时间的变化特性。为全面标定核测量仪表的反应堆周期测量性能,结合中子探测器输出信号微弱的特点,提出了基于数字技术实现反应堆周期信号模拟的方案。方案包括硬件和软件两方面,识别了关键问题,并设计解决了高精度定时和微弱信号输出问题。同时,研究了仪表的标定方法并按方法对反应堆周期信号输出的性能进行测试。在反应堆周期值为2 s~999 s的范围内,选取7个反应堆周期值进行测试,测试偏差绝对值的最大值为0.45%。
英文摘要:
      Aiming at calibration of reactor period measurement for reactor nuclear measuring instrumentation, the neutron multiplication characteristics of reactors were studied from the aspcet of theoretical derivation and verification of real stack data, and it was determined that signals with exponential variation laws can characterize the change characteristics of reactor neutron fluence rate over time. In order to fully calibrate the reactor period measurement performance of nuclear measurement instruments, considering the neutron detectors output signal weakly, it proposed a reactor period signal simulation scheme based on digital technology. The scheme includes both hardware and software aspects, identifying key issues, and designing solutions to high-precision timing and weak signal output issues. At the same time, the calibration method was studied, by which the reactor period signal output performance was tested. Within the range of reactor period values from 2 s to 999 s, seven values were selected for testing, and the maximum absolute value of the test deviation was 0.45%.