贺三军,赵修良*,刘丽艳,曹光辉,练德幸.222Rn/220Rn绝对测量小闪烁室的ZnS(Ag)涂层厚度确定[J].南华大学学报(自然科学版),2012,26(1):19~23.[HE San-jun,ZHAO Xiu-liang*,LIU Li-yan,CAO Guang-hui,LIAN De-xing.ZnS(Ag) Coating Layer Thickness Verification of One Small Scintillation Cell for 222Rn/220Rn Absolute Measurement[J].Journal of University of South China(Science and Technology),2012,26(1):19~23.]
222Rn/220Rn绝对测量小闪烁室的ZnS(Ag)涂层厚度确定
ZnS(Ag) Coating Layer Thickness Verification of One Small Scintillation Cell for 222Rn/220Rn Absolute Measurement
投稿时间:2012-02-08  
DOI:
中文关键词:  ZnS(Ag)  涂层厚度  小闪烁室  222Rn/220Rn  绝对测量
英文关键词:ZnS(Ag)  coating layer thickness  small scintillation cell  222Rn/220Rn  absolute measurement
基金项目:2009年湖南省教育厅研究生科研创新基金资助项目(2009CXJJ4)
作者单位
贺三军,赵修良*,刘丽艳,曹光辉,练德幸 南华大学 核科学技术学院,湖南 衡阳 421001 
摘要点击次数: 1164
全文下载次数: 1181
中文摘要:
      ZnS(Ag)涂层厚度会影响222Rn/220Rn绝对测量小闪烁室的探测效率.用241Amα电镀参考源对厚度为10 mg/cm2的ZnS(Ag)涂层α探测效率进行了实验验证.分别采用解析方法与MCNP模拟方法计算了相对立体角修正因子,讨论了空气层对α粒子的吸收修正,分析了不确定度来源.实验结果表明,10 mg/cm2 ZnS(Ag)涂层对α粒子的探测效率在102.4%~103.1%之间,不确定度小于5.44%.在实验不确定度范围内,可认为其对α粒子的探测效率为100%.实验证明了222Rn/220Rn绝对测量小闪烁室内采用10 mg/cm2厚的ZnS(Ag)涂层是可行的.
英文摘要:
      The detection efficiency of one small scintillation cell for 222Rn/220Rn absolute measurement can be affected by ZnS (Ag) coating layer thickness on the inner wall of the small scintillation cell.The α detection efficiency of 10 mg/cm2 thickness ZnS (Ag) coating layer has been tested and verified using a plating reference source (241Am).The solid angle correction factor is calculated by analysis and MCNP simulation methods.The absorption correction of air layer on α particle has been discussed.The source of uncertainty has been analysed.The results indicate the α detection efficiency of 10 mg/cm2 thickness ZnS (Ag) coating layer is between 102.4%~103.1% while the uncertainty is less than 5.44%.In the uncertain range α detection efficiency of it is considered as 100%.10 mg/cm2 thickness ZnS (Ag) coating layer can be used to apply on the inner wall of the small scintillation cell for