杨胜园,陈云生,于军晖,杨慧仙,饶培黎.镉-溴化钾-邻菲罗啉共振光散射法测定痕量镉的研究[J].南华大学学报(自然科学版),2009,23(1):89~91.[YANG Sheng-yuan,CHEN Yun-sheng,YU jun-hui,YANG Hui-xian,RAO Pei-li.Determination of Trace Cadmium with Ternary Complex of Cd2+- Bromatum Kalium-Phenanthroline by Resonance Light Scattering[J].Journal of University of South China(Science and Technology),2009,23(1):89~91.] |
镉-溴化钾-邻菲罗啉共振光散射法测定痕量镉的研究 |
Determination of Trace Cadmium with Ternary Complex of Cd2+- Bromatum Kalium-Phenanthroline by Resonance Light Scattering |
投稿时间:2008-12-20 |
DOI: |
中文关键词: 镉 溴化钾 邻菲罗啉 共振光散射 |
英文关键词:Cadmium Bromatum Kalium Phenanthroline Resonance light scatting |
基金项目:湖南省卫生厅基金资助项目(B2007096) |
|
摘要点击次数: 715 |
全文下载次数: 1037 |
中文摘要: |
在pH 9.0的KH2PO4-NaOH缓冲液中,Cd2+与溴化钾、邻菲罗啉反应生成多元配合物导致体系共振光散射强度增大,在λ = 470.3 nm处共振光散射增大程度与镉的浓度有良好的线性关系.方法线性范围为:0.04~2.68 μg/mL,检出限为1.28×10-2 μg /mL,相对标准偏差为0.98%和1.68%,样品加标回收率为91.8%~104.7%. |
英文摘要: |
A new resonance light scattering method for determination of trace cadmium has been studied in the KH2PO4-NaOH buffer solution at pH 9.0 and in the presence of CTMAB.Under the selected conditions,the enhancement of resonance light scattering (RLS) at 473.0nm was linear to the concentration of Cd2+ ranging from 0.04~2.68 μg/mL.The detection limit was 12.8 ng/mL and the RSD were 0.98%,1.68%respectively.The recovery were 91.8%~104.7%. |
查看全文 查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|