陈海辉,曾莹莹.地铁屏蔽门环控系统的经济分析[J].南华大学学报(自然科学版),2003,(4):33~37.[.Economic Analysis for the Environment Control Mode with Metro Platform Screen Doors[J].Journal of University of South China(Science and Technology),2003,(4):33~37.] |
地铁屏蔽门环控系统的经济分析 |
Economic Analysis for the Environment Control Mode with Metro Platform Screen Doors |
修订日期:2003-03-12 |
DOI: |
中文关键词: 地铁屏蔽门 环境控制 经济分析 |
英文关键词:metro Platform Screen Doors,environment control,economic analysis, |
基金项目: |
陈海辉 曾莹莹 |
陈海辉(南华大学,机械工程学院,湖南,衡阳,421001) 曾莹莹(南华大学,机械工程学院,湖南,衡阳,421001)
|
摘要点击次数: 817 |
全文下载次数: 3 |
中文摘要: |
简介地铁环境控制的三种模式,分析了屏蔽门模式环境控制的特性及负荷模拟计算,对三种地铁环境控制模式进行经济分析比较,分析表明屏蔽门模式经济性最佳. |
英文摘要: |
Three control modes of subway environment are briefly introduced in this paper. The feature of environment control and simulated calculation of cooling load in the mode of platform screen doors are analyzed. Economic contrast among the three modes of subway environment control is reckoned, which proves that the mode of platform screen doors is the best economical way. |
查看全文 查看/发表评论 下载PDF阅读器 |