肖德涛,左富琪,曹扬达,赵桂芝,林祖滨,邱小平.空气净化器净化室内氡子体效率的检测[J].南华大学学报(自然科学版),1997,(2):.[.Testing of Efficiency of Air Cleaners to Reduce Radon Daughters[J].Journal of University of South China(Science and Technology),1997,(2):.] |
空气净化器净化室内氡子体效率的检测 |
Testing of Efficiency of Air Cleaners to Reduce Radon Daughters |
|
DOI: |
中文关键词: 空气净化器,α潜能浓度,瞬时氡浓度,平衡因素 |
英文关键词: |
基金项目: |
肖德涛 左富琪 曹扬达 赵桂芝 林祖滨 邱小平 |
中南工学院技术物理系!衡阳,421001 |
摘要点击次数: 1147 |
全文下载次数: 4 |
中文摘要: |
净化空气中的氡子体是室内降氡技术手段之一.为了有效地检测空气净化器净化室内空气中氡子体的效率,设计了一套远距离测量α潜能浓度(Cp)的系统,并将该系统在容积为13.5m3的标准氡室里进行了严格的刻度.同时测量Cp和瞬时氡浓度(CRn)就可以求出可比的平衡因数F,对完善该检测方法进行了讨论. |
英文摘要: |
Purifying radon daughters in air is one of the techniques of raducing indoor radon. In order to test the efficiency of Turbo-88 Air cleaners produced by Foshan Aercology Air Cleaning System, Ltd. to reduce radon daughters in indoor air, a special a potential energy concentration measurement system was developed and Calibrated in a standard radon chamber with a volume of 13. 5m3. When 2 potential energy concentration were measured simutaneously the average equilibrium factor with comparability can be calculated.The improvement of the testing is discussed as well. |
查看全文 查看/发表评论 下载PDF阅读器 |